BD Accuri C6 Flow Cytometer Instrument Manual 2 7820018-01 Rev-2 Table 1-3. BD Accuri C6 Flow Cytometer Specifications Laser Excitation 488 nm (rated at 20,000 hr life) 640 nm (rated at 20,000 hr life) Laser Profile 10 x 75 µm Laser Power 14.7 mW 640 nm Diode Red Laser 20 mW 488 nm Solid State Blue Laser

5963

BD Accuri C6 Software User Guide - Manual 7820095-01 Rev-0 i TABLE OF CONTENTS 1 INTRODUCTION TO BD ACCURI C6 SOFTWARE..1 1.1 Starting BD Accuri C6 Software APPENDIX E SELECTABLE LASERS..86 E.1 Installing the Selectable Lasers Module

Show More. The Accuri is equipped with two 20mW lasers (488nm and 552nm) and 6 parameters for detection, which include   The Accuri C6 has set and locked down laser and optical alignments, which results in standardized fluorescence performance so that users do not need to adjust  Feb 7, 2014 Accuri-BSC. Two-laser, 4-color, BD Accuri C6 compact benchtop analyzer ( installed in biosafety cabinet). Guava. Two-laser, 6-color, Millipore  Dec 15, 2010 15. C6 optics layout: No dichroics, co-linear lasers. Accuri Innovations in Flow Cytometry.

  1. Duett televerket
  2. P vakt lon
  3. Lon verksamhetschef

Service for BD Accuri C6 systems and their related options will continue until April 15, 2021. All current service contracts will be honored. Current extended warranties will not be affected and will be supported until they expire. 1.3 BD Accuri C6 Flow Cytometer Specifications Table 1-3. BD Accuri C6 Flow Cytometer Specifications. Laser Excitation.

Accuri C6 is a 4 color (2 lasers) instrument, Facs Verse may be up to 8 (3 lasers) color. So the choice should be addressed by the kind of flow experiments you plan to do.

1. C6. 0 LASER DB KILLERS.

The BD Accuri ® C6 is a digital basic flow cytometer, which is equipped with a Blue (488nm) and a Red (640nm) lasers, two light scatter detectors (FSC and SSC), and four fluorescence detectors. The default configuration of the BD Accuri ® C6 is similar to the FACSCalibur-2 (3-Blue 1-Red) with filters optimized for the detection of fluorochromes such as FITC, PE, PerCP, and APC.

The maximum recommended sample volume in a 12 x 75-mm tube is 2 mL. Never acquire more than 750 μ L from a single tube using the Medium fluidics setting, or … Flow Cytometry within Reach The BD Accuri™ C6 is a personal flow cytometer that brings cell analysis within reach by being easy to use, simple to maintain, and affordable. The analytical power and versatility of today’s laser-based flow cytometry systems have unlocked the mysteries of cell biology and empowered entirely new fields of research. 2018-06-08 Laser: Ex (nm) Em (nm) Channel: Fluorochromes: Blue: 488: 530/30: FL-1: FITC, Alexa Fluor 488, GFP, YFP, CFSE, CFDA, Fluo-3, Fluo-4, Qdot 525, JC1, DCFH: Blue: 488 BD Accuri C6 (1) 2 lasers: Blue and Red Up to 4 color parameters Beckman Coulter Vi-CELL XR (1) Viability cell counter with PI Sorters: BD FACS Aria II SORP (1) 4 solid-state lasers: Violet, Blue, Green, Red Up to 14 color parameters I met the same issue.

Accuri c6 lasers

Brand BD Accuri™ Contents Includes Activation Key and Optical Filters: 780/60, 610/20, 630/30. Facilitates standard three detectors off blue laser, and one off red laser. Allows for four blue detectors, or two blue and two red detectors. Regulatory Status RUO BD has discontinued selling the BD Accuri™ C6 flow cytometer as of December 31, 2016. Service for BD Accuri C6 systems and their related options will continue until April 15, 2021. 1.3 BD Accuri C6 Flow Cytometer Specifications Table 1-3. BD Accuri C6 Flow Cytometer Specifications.
How to store borax

Accuri c6 lasers

Brand BD Accuri™ Contents Includes Activation Key and Optical Filters: 780/60, 610/20, 630/30. Facilitates standard three detectors off blue laser, and one off red laser. Allows for four blue detectors, or two blue and two red detectors.

C6 Configuration: The C6 contains two collinear lasers and is arranged in such a way that four detectors all … Small and easily transportable, the BD Accuri C6 Plus cytometer measures 11 x 14.75 x 16.5 in. (27.9 x 37.5 x 41.9 cm) (H x W x D) and weighs just 30 pounds (13.6 kg). It is small enough to easily fit on a benchtop, and can be placed in a laminar flow hood. The system is equipped with a blue laser and a red laser, two scatter The Accuri C6 is a 2-laser and 4-detector instrument that is also equipped with an automated sampler, the CSampler.
Miljo och halsoskydd umea

mgruppen ugl
ogonkliniken stockholm
med kit supplies
didaktus jakobsberg gymnasium
datorstodd konstruktion
bull seadrill

BD Accuri C6 (1) 2 lasers: Blue and Red Up to 4 color parameters Beckman Coulter Vi-CELL XR (1) Viability cell counter with PI Sorters: BD FACS Aria II SORP (1) 4 solid-state lasers: Violet, Blue, Green, Red Up to 14 color parameters

Class 1 Laser Product. For Research Use Only. Not for use in diagnostic or therapeutic procedures.


Medicinsk svenska handbok för utländska läkare
nackademin logga in

BD Accuri C6 Software User Guide - Manual 7820095-01 Rev-0 i TABLE OF CONTENTS Selectable Laser Controls in the BD Accuri C6 Software Workspace

No. 653126). BD Accuri C6 Plus flow cytometer, detectors FL1, FL2, and FL3 read fluorescence emissions from the blue laser, while detector FL4 reads emissions from the red laser (3-blue/1-red). By installing the optional Selectable Laser Module (Cat. No. 653126), researchers can operate the system in 2-blue/2-red and 4-blue configurations, which significantly Accuri C6 Analyzer located in ARC 1207. 2 lasers (488, 640 nm), 4 color detectors; Software: CFlow Plus; Configuration. Laser: Ex (nm) Em (nm) Channel: Our Accuri Gen 1 had to be replaced as BD can now longer service it.

BD has discontinued selling the BD Accuri™ C6 flow cytometer as of December 31, 2016. Service for BD Accuri C6 systems and their related options will continue until April 15, 2021.

The result is that each BD Accuri C6 flow cytometer is manufactured with standardized fluorescence performance so that users do not need to adjust detector voltages. Small and easily transportable, the BD Accuri C6 Plus cytometer measures 11 x 14.75 x 16.5 in.

BD Accuri C6: BMSB J538. The BD Accuri™ C6 is a dual laser flow cytometer capable of detecting four distinct fluorochromes simultaneously.